EDX-MAX PLUS X-ray fluorescence sulfur analyzer
Collect
商品说明
At present, the control of sulfur content in petrochemical products such as gasoline, diesel and lubricating oil has become the core of environmental protection supervision worldwide. The sulfur dioxide produced by the combustion of high-sulfur oil products will be converted into sulfate, which not only accelerates the corrosion of engine components but also leads to the failure of exhaust catalytic converters. Meanwhile, the emission of sulfur oxides is the main cause of acid rain. The EDX-MAX PLUS X-ray fluorescence sulfur analyzer launched by Comas Instruments strictly complies with the sulfur content detection requirements of "GB 252-2015 General Diesel" and "GB 17411-2015 Marine Fuel Oil". It has an ultra-small helium-filled sample chamber and an ultra-close testing distance, and can quickly test the sulfur content in the oil body. It can also measure the content of elements from sodium to uranium. Moreover, this instrument is easy to operate, highly stable, has a wide testing range, fast analysis speed and low detection limit. 商品参数
Application field Petrochemicals, crude oil extraction, liquid elemental analysis Performance advantage The instrument has a compact and smooth appearance, is simple and elegant, and is easy to use The ultra-small helium-filled sealed sample chamber saves gas consumption and reduces detection costs Ultra-short sample testing distance enhances the accuracy of sample testing The speed of analyzing samples is fast Each sample test is highly consistent, ensuring the accuracy of the test data, saving standard samples, and eliminating the need for special sampling tools The downlit design prevents sample evaporation from contaminating the light tube and the beryllium window of the detector. It can measure light oils such as gasoline and diesel, improving the testing accuracy High-excitation efficiency side-window W-target X-ray tube, large-area SDD detector, and excellent heat dissipation effectively ensure the high efficiency and stability of the test The X-ray shielding design ensures that testers can use it safely and with peace of mind Standard configuration Seal the sample chamber with helium gas SDD detector Signal detection electronic circuit High and low voltage power supply Open sample platform Intelligent sulfur measurement software X-ray tube Computers and inkjet printers Technical parameters Elemental analysis range :Na-U Analysis range :3ppm-99.99% Detection limit :10ppm(up to 3ppm when filled with helium) Functional scope: Specialized petroleum element analysis Measurement time :50-100 seconds Measured object: Liquid Working voltage :AC 110V/220V Operating temperature :10-35℃ |